Procedure - Solid Samples

Determine the instrument blank.

Repeat steps 2b through 2g a minimum of three times.


Set the blank following the procedure outlined in the operator's instruction manual.


Instrument calibration/drift correction.

Login a minimum of 3 Standard replicates.


Weigh approximately *** grams of a calibration/drift standard, enter the mass and standard identification into appropriate replicate fields.



Note: LECO Reference Materia***o not require preparation.See preparation statement on the reference material certificate.





***触摸屏技术,用户友好界面软件进行校正、分析、诊断等。元素分析仪多少钱

Summary


The determination of the amount of oxygen, nitrogen, and hydrogen in iron, steel, nickel-, and cobalt-base alloys represents some of the most important quality metrics for these materials. Oxygen is used to create steel from pig iron by removing excess carbon. Oxygen content must be controlled to limit the amount of carbon monoxide that can be formed during solidification which may cause excessive porosity. Nitrogen is considered both an impurity as well as an important alloying agent. Itcan be present as a nitride or interstitially in its gaseous form. Increased nitrogen content is known to increase yield and tensile strength, thus decreasing ductility and formability. Excessive levels may evolve during solidification thus increasing porosity. High hydrogen content is the primary cause of embrittlement, blistering and flaking due to its high

mobility through the lattice and provides no potential alloying benefits. The ONH836 utilizes a high-power

electrode furnace to quickly and efficiently release the target gases from within the sample, which allows

for a very rapid simultaneous determination of oxygen, nitrogen, and hydrogen.


北京专业分析仪供应商分析软件同时包括实时的环境参数的监测,提供完整的系统图表的模拟。

736 Series: Oxygen/Nitrogen by Inert Gas Fusion


The 736 family of Elemental Analyzers is designed for routine measurement of oxygen and nitrogen content of

inorganic materials, ferrous and nonferrous alloys, andrefractory materials using the inert gas fusion technique.

These instruments feature our Cornerstone brand ® software, a custom interface designed specifically for

touch-screen operation. Developed by combining longterm research with customer feedback, this easy-to-use

software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.


氧氮氢分析仪的使用注意事项:

1 、氧氮氢分析仪在初次启用前,应该对连接点、焊点、阀门等进行检漏,以确保空气中的氧不会反渗进入管道及仪器内部,造成测量数值偏高。

2、再次使用仪器前,要进行管道系统净化,将漏入的空气除干净,同时确保连接取样管路时没有漏入空气。

3、样气中氧含量的变化会受管道材质及表面粗糙度影响,因此一般连接管路选用铜管或抛光过的不锈钢管,而不用塑料管、橡胶管等。

4、微量元素分析时,要避免各种管件、阀门、表头等死角对样气造成污染,因此必须尽可能的简化气路系统,连接件死角要小,以防止溶解氧逸出造成污染,使用水封、油封及腊封等设备,才能较好的确保数据的。


长寿命的红外发射光源和无漂移的电路设计保证红外检测池的长期稳定性。

Procedure – Powder/Chip Samples

Instrument calibration/drift correction.

Add approximately 0.05 g of *** Graphite Powder to a***Graphite Crucible.

Firmly place the crucible on the lower electrode tip or appropriate autoloader position.

Press the Analyze button on the instrument screen,the lower electrode will close and the analysis sequence will start and end automatically.

Repeat steps 3b through 3i a minimum of three times for each calibration/drift standard used.

Cornerstone氧氮氢分析软件同时支持***的数据文档格式和可变的报告格式。浙江分析仪厂家供应

20位试样自动进样系统。元素分析仪多少钱

Instrument calibration/drift correction.

a. Login a minimum of 3 Standard replicates.

b. Weigh a ~1.000 gram of a calibration/drift standard, enter the mass and standard identification into appropriate replicate fields.

c. Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.

d. Place the calibration/drift standard into the open port at the top of the loading head.

e. Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.