首页 >  仪器仪表 >  元素分析仪厂家供应「上海禹重实业供应」

分析仪基本参数
  • 品牌
  • LECO
  • 型号
  • 齐全
分析仪企业商机

Oxygen, Nitrogen, and Hydrogen in Refractory Metals

Summary

Oxygen and nitrogen are alloying elements in titanium, and are also classified as alpha stabilizing elements as they promote alpha phase alloys. Interstitial oxygen and nitrogen levels can be used to regulate the tensile strength of the material, but due to its high solubility can cause unwanted surface embrittlement. This phenomenon can be leveraged,however, under controlled processing to create surface films that increase surface hardness and wear properties.

力可***仪器采用触摸屏技术和在线软件平台,增强了仪器的可操作性、降低了分析成本、节省实验室桌面空间。元素分析仪厂家供应

Procedure – Powder/Chip Samples

Instrument calibration/drift correction.

Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.

Place the Nickel Capsule containing the sample into the open port at the top of the loading head.

Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.

Clean the upper and lower electrode either manually or remove the crucible and press the analyze button to clean with an automatic cleaner if applicable.



元素分析仪厂家供应全自动分析系统、打印机、天平、远程诊断。

力可ONH836氧氮氢分析仪

特点和优势

国际**的非色散红外及热导检测器 ,无移动部件,不需要手动调整

采用三个**的红外器检测氧含量,同时检测CO和CO2,然后在转化为CO2集中检测,原理上是**完善的,所以不仅可以保证中间量程的测量精度,在**含量和高含量的检测范围内同样可以满足精度要求

高性能的红外检测器配置***恒温绝热技术,消除了外界环境温度的干扰

长寿命的红外发射光源和无漂移的电路设计保证检测器的长期稳定性

力可**的动态流量补偿控制DFC系统,保证了流量系统的完善,可以精确控制整个气路中的流量,保持流量恒定**改善了材料中氮分析的准确度

可以旁路的OMI-2 气路强化过滤装置增强了检测器的稳定性,使得分析结果更加准确

可选自动功能

20位试样自动进样系统

通用下电极坩埚支座,容纳各种坩埚使用

无需人工干预的全自动清扫系统



Procedure – Powder/Chip Samples

Determine the instrument blank.


Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.


Repeat steps 2b through 2g a minimum of three times.


Set the blank following the procedure outlined in the operator's instruction manual.


Instrument calibration/drift correction.

Login a minimum of three Standard reps.


Weigh approximately *** grams of a calibration/drift standard into a *** Nickel Capsule; enter the mass and standard identification into appropriate rep fields. If applicable, place the nickel capsule in the appropriate autoloader position.


Note: LECO Reference Materia***o not require preparation. See preparation statement on the reference material certificate. Solid Standards may be used to calibrate when chip or powder standards are not available.




用户友好界面的Cornerstone™ 软件。

Procedure - Solid Samples

Instrument calibration/drift correction.

Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.

Firmly place the crucible on the lower electrode tip or appropriate autoloader position.

Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.

Repeat steps 3b through 3j a minimum of three times for each calibration/drift standard used.

Calibrate/drift following the procedure outlined in the operator's instruction manual.


**的动态流量补偿(DFC)保证热导池气体流量、压力恒定。山东LECO氧氮氢分析仪

稳固的炉头试样加载结构。元素分析仪厂家供应

ONH836系列:氧氮氢分析仪(熔融法)

力可ONH836系列仪器采用惰性熔融法,提供各种无机材料、钢铁、有色金属、硬质合金、陶瓷材料中宽范围的氧氮氢同时分析。

ONH836系列仪器通过***采纳客户的反馈意见和创新设计,力可***仪器采用触摸屏技术和在线软件平台,增强了仪器的可操作性、降低了分析成本、节省实验室桌面空间。


用户友好界面的Cornerstone™ 软件

力可**的Cornerstone 氧氮氧分析软件采用触摸屏界面使用户可完整的达到分析控制、方法设定、在线诊断、数据报告。Cornerstone  氧氮氧分析软件允许用户在单一分析界面中完成日常的所有工作,快速而且简单易用。力可创新的批次和重复样品数据分组功能极大简化了样品结果输出和结果标准偏差的自动计算,减少了繁琐的额外数据处理。