Instrument Highlights and Features
Features and Benefits
LED light ring illuminates the furnace area
Choice of either argon or helium carrier gas
Novel electrode design increases heat transfer efficiency for increased stability
Non-touch interface systems are also available
User-friendly brand software
High-Performance Detector Design
Thermostatic construction provides increased protection from ambient temperature fluctuations
Optimized emitter control and detection circuitryimproves the IR cell lifetime and long-term stability,
resulting in superior accuracy and precision
Infrared detection for the determination of oxygen, thermoconductivity detection for the determination
of nitrogen
提供各种无机材料、钢铁、有色金属、硬质合金、陶瓷材料中宽范围的氧氮氢同时分析。广东LECO分析仪
Procedure - Solid Samples
Prepare the instrument as outlined in the operator's instruction manual.
Determine the instrument blank.
Login a minimum of 3 Blank replicates.
Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open. Place a 502-344 Nickel Basket into the loading head.
Note: samples using automation should be placed in the appropriate autoloader position before starting the
analysis sequence. Once the sequence has started, the automatic analysis will start and end automatically.
Procedure - Solid Samples
Determine the instrument blank.
Repeat steps 2b through 2g a minimum of three times.
Set the blank following the procedure outlined in the operator's instruction manual.
Instrument calibration/drift correction.
Login a minimum of 3 Standard replicates.
Weigh approximately *** grams of a calibration/drift standard, enter the mass and standard identification into appropriate replicate fields.
Note: LECO Reference Materia***o not require preparation.See preparation statement on the reference material certificate.
Oxygen, Nitrogen, and Hydrogen in Refractory Metals
Summary
Titanium is a metal that can be combined with elements such as aluminum, vanadium, molybdenum, and tin to produce high-strength, lowdensity, and corrosion-resistant alloys. Titanium alloys are used by the military, medical devices, sporting goods, and aerospace industries because of these properties, and due to the strict demands of these industries, effort needs to be taken to assure that the material meets the highest of quality standards.
配置SmartLine® Remote远程诊断功能。
Procedure - Solid Samples
Instrument calibration/drift correction.
Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.
Firmly place the crucible on the lower electrode tip or appropriate autoloader position.
Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.
Repeat steps 3b through 3j a minimum of three times for each calibration/drift standard used.
Calibrate/drift following the procedure outlined in the operator's instruction manual.
力可**的动态流量补偿控制DFC系统,保证了流量系统的完善,可以精确控制整个气路中的流量。广东LECO分析仪
Oxygen, Nitrogen, and Hydrogen in Refractory Metals
Summary
Oxygen and nitrogen are alloying elements in titanium, and are also classified as alpha stabilizing elements as they promote alpha phase alloys. Interstitial oxygen and nitrogen levels can be used to regulate the tensile strength of the material, but due to its high solubility can cause unwanted surface embrittlement. This phenomenon can be leveraged,however, under controlled processing to create surface films that increase surface hardness and wear properties.