Procedure – Powder/Chip Samples
Prepare the instrument as outlined in the operator's instruction manual.
Login a minimum of three Blank reps.
Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open. Insert a *** Nickel Capsule (leave capsule open) into the open port at top of loading head.
Note: samples using automation should be placed in the appropriate autoloader position before starting the analysis sequence. Once the sequence has started, the automatic analysis will start and end automatically.
Procedure – Powder/Chip Samples
Instrument calibration/drift correction.
Add approximately 0.05 g of *** Graphite Powder to a***Graphite Crucible.
Firmly place the crucible on the lower electrode tip or appropriate autoloader position.
Press the Analyze button on the instrument screen,the lower electrode will close and the analysis sequence will start and end automatically.
Repeat steps 3b through 3i a minimum of three times for each calibration/drift standard used.
上海专业元素分析仪厂家报价试样加载过程中完全密闭,消除大气的中可能带来的杂质的污染。氧氮氢分析仪的优点
采用惰气熔融技术,同时测定氧、氮和氢元素含量
新设计封闭气路系统,优化气路循环,使氧氮氢测量更准确
可采用更廉价的氩气作为载气
催化炉温度可调,使氧的测量更加准确
气路系统都采用电磁阀控制,新增分段式漏气检测
水冷样品加样端口,有效隔绝杂质气体侵入
仪器配置和氧、氮、氢测量范围可灵活选择
新设计的高灵敏度红外检测池和热导池,有极低的检出限
分析时间短
脉冲炉功率高达8.5kw,温度3000℃
颗粒状样品无需胶囊包裹,使用经济实惠
化学试剂及管路隐藏在门后(可移除)
强大的分析软件(支持数据和应用报告导出、增加评论区及其他更多功能)。
单点和多点校正(线性回归)
可采用自来水、冷却循环水机或交换机冷却
新设计的产品可用于各类生产控制和实验室。
Procedure – Powder/Chip Samples
Instrument calibration/drift correction.
Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.
Place the Nickel Capsule containing the sample into the open port at the top of the loading head.
Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.
Clean the upper and lower electrode either manually or remove the crucible and press the analyze button to clean with an automatic cleaner if applicable.
736 Series: Oxygen/Nitrogen by Inert Gas Fusion
The 736 family of Elemental Analyzers is designed for routine measurement of oxygen and nitrogen content of
inorganic materials, ferrous and nonferrous alloys, andrefractory materials using the inert gas fusion technique.
These instruments feature our Cornerstone brand ® software, a custom interface designed specifically for
touch-screen operation. Developed by combining longterm research with customer feedback, this easy-to-use
software gives you complete access to instrument control, analysis settings, diagnostics, reporting, and more—without sacrificing valuable bench space.
氧氮氢分析仪怎么选?欢迎联系上海禹重科技,我司产品质量保证,欢迎咨询!湖南LECO氧氮氢分析仪价格
稳固的炉头试样加载结构。新疆LECO氧氮氢分析仪多少钱
Oxygen, Nitrogen, and Hydrogen in Refractory Metals
Summary
One of the most critical chemical specifications of titanium alloys is the hydrogen content. Too high of a
hydrogen content can cause hydrides to precipitate, which can lead to embrittlement and subsequent
cracking when the alloy is stressed. Hydrogen pickup typically occurs during downstream processing steps
such as heat treating, pickling, and cleaning.
The LECO ONH836 is a simultaneous oxygen, nitrogen, and hydrogen determinator that utilizes an electrode furnace, inert carrier gas, and both infrared and thermal conductivity detection to meet the analytical needs of the refractory metal industry.
This application note was written specifically for use with the LECO ONH836 series determinator.