首页 >  仪器仪表 >  山西分析仪厂家报价「上海禹重实业供应」

分析仪基本参数
  • 品牌
  • LECO
  • 型号
  • 齐全
分析仪企业商机

氧氮氢分析仪是快速、准确分析氧、氮、氢元素的、高性能仪器,整机采用模块化、一体化设计,即主机由可靠的脉冲电极炉、高灵敏高精度的检测系统、布局合理和气密性好的气路系统、可靠耐用的电源系统、稳定的电路系统、高校节能的水循环散热系统等六个**的硬件模块单元组成。

氧氮氢分析仪的测量原理:

测量范围非常***。分析样品时,样品被称重后放到样品端口中,然后用载气进行冲洗,防止大气(含氧气和氮气)进入到炉子系统中。

石墨坩埚在脉冲炉中脱气,以尽量减少自带的污染。经过稳定阶段后样品落入坩埚中并熔融。样品中的氧与石墨坩埚中的碳反应生成一氧化碳。氮和氢以单质的形式释放。载气和样品气体通过粉尘过滤网后再进入到氧化铜催化炉中,将一氧化碳氧化成二氧化碳。

二氧化碳进入到红外池中用于测定氧含量,被测后的气体导入化学试剂管,这时二氧化碳和水被化学试剂除去,氮元素通过热导检测池含量被测定。测量氢时,载气换为氮气,样品气体通过舒茨试剂而不是氧化铜催化剂。测氧和氮时也可采用更廉价的氩气作为载气。 ***红外池的恒温绝热技术消除了外界环境温度的干扰。山西分析仪厂家报价

Procedure - Solid Samples

Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.


Clean the upper and lower electrode manually, or, if applicable, remove the crucible and press the analyze button to clean with the automatic cleaner


Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.


Firmly place the crucible on the lower electrode tip or appropriate autoloader position.


Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically



浙江美国LECO分析仪厂家供应简化日常分析所需的炉头进样部分机械维护工作。

Procedure – Powder/Chip Samples

Determine the instrument blank.


Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.


Repeat steps 2b through 2g a minimum of three times.


Set the blank following the procedure outlined in the operator's instruction manual.


Instrument calibration/drift correction.

Login a minimum of three Standard reps.


Weigh approximately *** grams of a calibration/drift standard into a *** Nickel Capsule; enter the mass and standard identification into appropriate rep fields. If applicable, place the nickel capsule in the appropriate autoloader position.


Note: LECO Reference Materia***o not require preparation. See preparation statement on the reference material certificate. Solid Standards may be used to calibrate when chip or powder standards are not available.




Instrument calibration/drift correction.

a. Login a minimum of 3 Standard replicates.

b. Weigh a ~1.000 gram of a calibration/drift standard, enter the mass and standard identification into appropriate replicate fields.

c. Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.

d. Place the calibration/drift standard into the open port at the top of the loading head.

e. Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.


高性能的红外检测器配置***恒温绝热技术,消除了外界环境温度的干扰。

Oxygen, Nitrogen, and Hydrogen in Refractory Metals

Summary

Titanium is a metal that can be combined with elements such as aluminum, vanadium, molybdenum, and tin to produce high-strength, lowdensity, and corrosion-resistant alloys. Titanium alloys are used by the military, medical devices, sporting goods, and aerospace industries because of these properties, and due to the strict demands of these industries, effort needs to be taken to assure that the material meets the highest of quality standards.



无需人工干预的全自动清扫系统。上海进口分析仪厂家供应

氧氮氢分析仪选哪家?给你推荐上海禹重科技!山西分析仪厂家报价

Sample Preparation


Sampling and sample preparation of refractory metals such as titanium and zirconium is somewhat different from that of steel. Unlike steel samples, hydrogen is not as mobile in this group of materials; therefore, storage in liquid nitrogen or dry ice is not required. However, it is important to keep the sample cool when cutting or sectioning. Sample preparation for oxygen and nitrogen determination has beendifferent from that of hydrogen determination.



山西分析仪厂家报价

与分析仪相关的文章
与分析仪相关的问题
与分析仪相关的搜索
信息来源于互联网 本站不为信息真实性负责